• <strike id="cseqw"><noscript id="cseqw"></noscript></strike>
  • <strike id="cseqw"></strike>

    儀器網(wǎng)(yiqi.com)歡迎您!

    | 注冊(cè) 登錄
    網(wǎng)站首頁-資訊-專題- 微頭條-話題-產(chǎn)品- 品牌庫-搜索-供應(yīng)商- 展會(huì)-招標(biāo)-采購- 社區(qū)-知識(shí)-技術(shù)-資料庫-方案-產(chǎn)品庫- 視頻

    產(chǎn)品中心

    當(dāng)前位置:儀器網(wǎng)>產(chǎn)品中心> 深圳市達(dá)瑞博電子有限公司>其他儀器儀表>5960A Triple Point of Argon System ZL
    收藏  

    5960A Triple Point of Argon System ZL

    立即掃碼咨詢

    聯(lián)系方式:18938937317

    聯(lián)系我們時(shí)請(qǐng)說明在儀器網(wǎng)(www.vietnamtrade.org)上看到的!

    掃    碼    分   享
    為您推薦

    產(chǎn)品特點(diǎn)

    Breakthrough primary temperature standards capability
    Low uncertainty of 0.25 mK
    Temperature plateau

    詳細(xì)介紹

    公司介紹圖片.png


      深圳市達(dá)瑞博電子有限公司長(zhǎng)期出售及租賃進(jìn)口二手儀器儀表:網(wǎng)絡(luò)分析儀、頻譜分析儀、信號(hào)發(fā)生器、示波器、天饋線測(cè)試儀、多功能校準(zhǔn)器/傳感器模塊、手機(jī)綜合測(cè)試儀、噪聲系數(shù)分析儀、NI-GPIB卡、阻抗/LCR測(cè)試儀、音頻分析儀、藍(lán)牙測(cè)試儀、功率計(jì)、放大器、萬用表等各類儀器儀表。

     

       經(jīng)營(yíng)品牌:安捷倫Agilent(Keysight)、R&S羅德與施瓦茨、Tektronix泰克、Anritsu安立、SPIRENT思博倫、Giga-tronics、Advantest愛德萬、Aeroflex艾法斯、IFR、韓國(guó)興倉PROTEK、JDSU真康、FUJITSU 富士通、SUNGSAN、TESCOM泰仕康、Keithley吉時(shí)利、Fluke福祿克、LitePoint萊特波特等。
     聯(lián)系電話:
     張  梁:18938937317  
     廖先生:13421364554

     產(chǎn)品介紹圖片.png

    5960A Triple Point of Argon System

    5960A Triple Point of Argon System
    • 概述

    • 產(chǎn)品綜述

    • 技術(shù)指標(biāo)

    • 型號(hào)和配件

    • 相關(guān)文檔

    Breakthrough primary temperature standards capability

    • Low uncertainty of 0.25 mK

    • Temperature plateau duration longer than 30 hours

    • Four entrant wells with radial uniformity less than 0.05 mK

    • 480 mm total immersion depth

    • Argon purity of 99.9999 %

    • Multi-language display support

    The Fluke Calibration 5960A Triple Point of Argon System enables primary standards laboratories to realize the argon triple point using a consistent, reproducible process with the lowest uncertainty of any commercially available system. The Fluke Calibration system produces a 30-hour temperature plateau and provides multiple entrant wells to increase SPRT calibration efficiency and throughput.

    Low calibration uncertainty

    A number of technology advancements are designed into the Fluke Calibration 5960A system to achieve a low uncertainty of 0.25 mK. For example, the argon cell is carefully built with an ultra-clean process using 99.9999 % (six nines) purity argon resulting in an uncertainty factor from impurities of 0.015 mK. The deep, 480 mm immersion depth of the entrant well minimizes the effects of stem conduction to less than 0.01 mK and radial uniformity to less than 0.05 mK.

    High lab throughput

    The 5960A system utilizes liquid nitrogen (LN2) in a Dewar vessel surrounding an argon cell to achieve –189.3442 °C. A digital controller combined with a heater maintains a temperature plateau lasting up to 30 hours with 0.1 mK variation without using complicated pressure controls. By regular renewal of liquid nitrogen in the system, the plateau length can even be extended to four days. The system’s long, stable temperature plateau lets you carry out your SPRT calibrations with better quality and more efficiency. Four entrant wells increase lab productivity by allowing you to calibrate four SPRTs simultaneously.

    Ease of operation and maintenance

    The display panel of the 5690A provides a simple menu structure with soft function keys for setup and programming the argon system. The readout displays simultaneously the set-point temperature, actual control sensor temperature and percent heater power. The display is selectable in eight languages—English, French, Spanish, Italian, German, Russian, Chinese, and Japanese. Applying positive pressure with helium or dry nitrogen to an entrant well port prevents your SPRTs from being bound in the entrant well by freezing moisture. You can insert and remove SPRTs as desired from the system over the duration of a single plateau. Other systems require that you first melt the cell in order to add or remove an SPRT.

    Specifications
    Assigned value-189.3442 °C
    Argon gas purity99.9999 % (6N purity)
    Uncertainty (k=2)0.25 mK
    Length of plateau (0.1 mK)>30 hours
    Argon cell depth*160 mm
    Number of entrant wells4
    Radial uniformity0.05 mK
    Total immersion depth480 mm
    Entrant well inner diameter (ID)8.0 mm
    Argon gas volume13.4 moles (535 grams)
    Liquid nitrogen Dewar volume44.2 liters
    Display resolution0.001 °C
    Set-point accuracy0.1 °C (adjustable)
    Power requirements100 V to 115 V (± 10 %) 50/60 Hz, 230 W 230 V (± 10 %) 50/60 Hz, 230 W
    System fuse ratings 115 V: 2 A T 250 V
    230 V: 1 A T 250 V 
    Size (HxWxD) 952 mm x 673 mm x 483 mm (37.5 in x 26.5 in x 19 in) 
    Weight 94 kg (207 lbs) 
    *Measured from the bottom of the probe well to the surface of argon sample

     

     

    溫馨提示:

         本產(chǎn)品上標(biāo)的價(jià)格只是參考價(jià)格,因?yàn)槭袌?chǎng)價(jià)格影響波動(dòng)大,所以價(jià)格也會(huì)有影響,具體價(jià)格還請(qǐng)聯(lián)系客服,請(qǐng)勿直接下單,謝謝合作!

     

       如有需要,歡迎隨時(shí)聯(lián)系我們,謝謝!

      


     

     

     

     

     

     

     


    廠商推薦產(chǎn)品

    在線留言

    上傳文檔或圖片,大小不超過10M
    換一張?
    取消
    精品无码在线,九九精品综合人人爽人妻,亚洲一区在线尤物,伊人网在线18禁
  • <strike id="cseqw"><noscript id="cseqw"></noscript></strike>
  • <strike id="cseqw"></strike>